f-male-to-f-female-lightning-arrester---dc---3-ghz, f-male-to-f-female-lightning-arrester---dc---3-ghz, /rf-lightning-arrester
EN
This F Male to F Female lightning arrester is a GDT based RF surge protector designed for DC - 3 GHz operation. It sits in the transmission line between the antenna and the radio equipment, diverting lightning-induced transients to ground before they reach the sensitive front end. The 75 ohm design holds insertion loss at 0.2 dB with a VSWR of 1.3 or better across the passband.
Request a Quote | Download Datasheet | Ask an Engineer
Product Overview
This F Male to F Female lightning arrester is a 75 ohm surge protector for RF transmission lines operating from DC to 3 GHz. It uses a replaceable 90 V gas discharge tube (GDT) rated for 10 kA on an 8/20 us waveform. In normal service, the GDT remains high impedance so that the RF path can pass with 0.2 dB insertion loss. During a lightning-induced or switching transient, the tube ionizes rapidly and routes surge energy through the grounding lug rather than toward connected equipment.
As an RF surge protector, the unit is intended to protect antenna-line equipment while keeping the signal path practical for 75 ohm systems. The low-capacitance GDT design supports broad-band operation and allows the discharge element to be replaced after a significant event. Compared with diode solutions, a GDT has a higher operating threshold, but this arrangement is suitable where low loss and a serviceable protection element are important.
Protection Mechanism and Construction
Reference Technical Specifications
The values below describe this F Male to F Female lightning arrester and should be checked against the final production configuration for a specific order.
Parameter |
Specification |
Notes |
Connector Interface |
F Male to F Female |
Standard RF connector |
Mounting Style |
Bulkhead |
Body configuration |
Impedance |
75 ohm |
System impedance |
Frequency Range |
DC - 3 GHz |
Passband |
Insertion Loss |
0.2 dB |
Across passband |
VSWR |
1.3 |
Maximum |
Power Handling |
60 W |
CW, reference |
Discharge Element |
90 V |
Gas discharge tube |
Surge Current |
10 kA (8/20 us) |
8/20 us waveform |
Grounding |
Ring terminal |
M4 lug, ground wire |
Body Material |
Machined brass |
Corrosion-resistant plating |
Weight |
73.1 g |
Approximate |
Typical Application |
Satellite TV, CATV headend, LNB protection |
Primary use case |
Reference figures are provided for this protection family; confirm final values before specifying the product for a project.
Engineering Comparison
Applications
Installation and Grounding Notes
OEM and B2B Support
FAQ
Q: How often does the gas discharge tube need replacement?
A: The 90 V tube is rated for 10 kA (8/20 us). Following a major surge event, test the tube for leakage or hold-off performance. If replacement is required, the F Male to F Female lightning arrester can be serviced without replacing the full body.
Q: Will this F Male to F Female lightning arrester affect my DC - 3 GHz signal?
A: Its reference insertion loss is 0.2 dB and maximum VSWR is 1.3 across the stated passband. These values are intended to keep RF impact low in applicable antenna-line installations.
Q: Can I use this arrester indoors?
A: Yes. In addition to cable-entry placement for satellite TV surge protection, the RF surge protector can be installed near the equipment end of a cable run as a further protective stage.