N Male to N Female Lightning Arrester - DC - 6 GHz

This N Male to N Female lightning arrester is a GDT based RF surge protector designed for DC - 6 GHz operation. It sits in the transmission line between the antenna and the radio equipment, diverting lightning-induced transients to ground before they reach the sensitive front end. The 50 ohm design holds insertion loss at 0.3 dB with a VSWR of 1.35 or better across the passband.

Request a Quote  |  Download Datasheet  |  Ask an Engineer

Request a Quote WhatsApp
  • Overview

Overview

Product Overview

This N Male to N Female lightning arrester is an in-line RF surge protector for 50 ohm coaxial systems operating from DC to 6 GHz. It is intended for antenna feeders and radio-side cable entries where transient energy needs a controlled path to earth before it reaches sensitive equipment. A replaceable 90 V gas discharge tube (GDT) forms the protective element. In normal service, the GDT remains non-conductive so RF signals pass through the device; during a surge, it conducts and directs energy toward the grounding connection. The stated insertion loss is 0.3 dB across the passband, helping the unit fit into antenna-line applications where signal continuity is important.

The GDT design is selected for its low-capacitance signal path and serviceable protection element. Unlike a fixed component that requires the entire protector to be replaced after a significant event, the tube in this N Male to N Female lightning arrester can be inspected and changed when required. Because gas-discharge protection generally has a higher operating threshold than diode-based protection, system placement and grounding quality remain central considerations for outdoor RF installations.


Protection Mechanism and Construction

  • Protection Element: The unit uses a 90 V gas discharge tube rated for 10 kA on an 8/20 us surge waveform. Located in the central body, the tube is accessible for replacement without removing the connected cable assembly.
  • Grounding Path: A side-mounted ring terminal provides the connection to the site earth bar. The short, direct route from the GDT to ground is a practical part of the protection system because it limits the transient energy that can continue toward connected equipment.
  • Body: The bulkhead-format housing is machined brass with corrosion-resistant plating. This construction supports direct panel or bulkhead mounting at a cable entry or equipment boundary.
  • Connector Interface: N Male to N Female interfaces connect with standard RF cable assemblies. Use the applicable connector torque guidance during installation.


Reference Technical Specifications

The following reference values describe the N Male to N Female lightning arrester configuration. Confirm final values against the production configuration selected for the project.

Parameter

Specification

Notes

Connector Interface

N Male to N Female

Standard RF connector

Mounting Style

Bulkhead

Body configuration

Impedance

50 ohm

System impedance

Frequency Range

DC - 6 GHz

Passband

Insertion Loss

0.3 dB

Across passband

VSWR

1.35

Maximum

Power Handling

150 W

CW, reference

Discharge Element

90 V

Gas discharge tube

Surge Current

10 kA (8/20 us)

8/20 us waveform

Grounding

Ring terminal

M4 lug, ground wire

Body Material

Machined brass

Corrosion-resistant plating

Weight

119 g

Approximate

Typical Application

5G base station, DAS, small cell, tower-top equipment

Primary use case

These values are reference data for this protection family and should be checked against the final production configuration.


Engineering Comparison

  • vs. Quarter-Wave Stub: A quarter-wave solution is frequency-specific and can ground DC, so its useful range is narrower. With a DC - 6 GHz passband, this RF surge protector is suited to multi-band antenna lines that need one in-line protection point.
  • vs. Diode-Based Protector: Diode devices can clamp differently but may add capacitance to an RF path. The stated 0.3 dB insertion loss and 150 W reference power handling make this GDT configuration relevant for applicable transmitter-line installations.
  • vs. DC Block Surge Protector: A DC-blocking arrangement has a different function from an arrester that provides an earth path for surge energy. This unit is designed to route the discharge toward ground through its ring-terminal connection.


Applications

  • 5G base station, DAS, small cell, tower-top equipment: This N Male to N Female lightning arrester can be positioned in antenna-line systems to support 5G base station surge protection where induced transients are a concern.
  • Tower and Rooftop Installations: The bulkhead body can be mounted near a shelter, cabinet, or cable-entry point so the transmission line has a defined earth-reference connection at the installation boundary.
  • Multi-Band Radio Sites: Its DC - 6 GHz operating range can support sites using more than one applicable band without a frequency-specific retuning step.
  • Equipment Racks and Test Systems: The 6 GHz coaxial lightning protection point may be installed near equipment inputs or instruments connected by longer cable runs, adding a grounded protection stage before the RF front end.


Installation and Grounding Notes

  • Grounding First: For effective 5G base station surge protection, connect the grounding lug to the earth bar with the shortest practical lead. A long or undersized grounding route increases inductance and can reduce the benefit of the arrester.
  • Mounting: Install the bulkhead body with the grounding connection oriented toward the cable-entry arrangement and within the protected area defined by the site lightning-protection design.
  • Torque and Sealing: Tighten the N connector interfaces according to the connector manufacturer guidance. For outdoor locations, apply suitable weatherproofing over the connector interface.


OEM and B2B Support

  • OEM Customization: For volume orders, available options include custom connector combinations, 90 V or 230 V discharge-voltage alternatives, and special plating selections.
  • Cable Assembly Options: Factory-terminated jumper assemblies with the arrester pre-installed can be supplied for installations that need a ready-to-connect cable configuration.
  • Packaging and Marking: Individual protective packaging, custom labels, and batch test reports are available on request.


FAQ

Q: When should the gas discharge tube be replaced?

A: The 90 V tube is rated for 10 kA on an 8/20 us waveform. Following a major surge event, test the tube for leakage and hold-off performance. If it does not pass the relevant check, the tube can be replaced without changing the complete arrester.


Q: Will this N Male to N Female lightning arrester affect a DC - 6 GHz signal?

A: The reference insertion loss is 0.3 dB and the maximum VSWR is 1.35 across the passband. These values describe the expected RF impact for applicable antenna-line use and should be confirmed for the final configuration.


Q: Can this arrester be used indoors?

A: Yes. It can be fitted at an equipment-end cable run as well as at an entry point, creating an additional grounded protection stage for connected RF equipment.