This N Male to N Female lightning arrester is a GDT based RF surge protector designed for DC - 6 GHz operation. It sits in the transmission line between the antenna and the radio equipment, diverting lightning-induced transients to ground before they reach the sensitive front end. The 50 ohm design holds insertion loss at 0.3 dB with a VSWR of 1.35 or better across the passband.
Request a Quote | Download Datasheet | Ask an Engineer
Product Overview
This N Male to N Female lightning arrester is an in-line RF surge protector for 50 ohm coaxial systems operating from DC to 6 GHz. It is intended for antenna feeders and radio-side cable entries where transient energy needs a controlled path to earth before it reaches sensitive equipment. A replaceable 90 V gas discharge tube (GDT) forms the protective element. In normal service, the GDT remains non-conductive so RF signals pass through the device; during a surge, it conducts and directs energy toward the grounding connection. The stated insertion loss is 0.3 dB across the passband, helping the unit fit into antenna-line applications where signal continuity is important.
The GDT design is selected for its low-capacitance signal path and serviceable protection element. Unlike a fixed component that requires the entire protector to be replaced after a significant event, the tube in this N Male to N Female lightning arrester can be inspected and changed when required. Because gas-discharge protection generally has a higher operating threshold than diode-based protection, system placement and grounding quality remain central considerations for outdoor RF installations.
Protection Mechanism and Construction
Reference Technical Specifications
The following reference values describe the N Male to N Female lightning arrester configuration. Confirm final values against the production configuration selected for the project.
Parameter |
Specification |
Notes |
Connector Interface |
N Male to N Female |
Standard RF connector |
Mounting Style |
Bulkhead |
Body configuration |
Impedance |
50 ohm |
System impedance |
Frequency Range |
DC - 6 GHz |
Passband |
Insertion Loss |
0.3 dB |
Across passband |
VSWR |
1.35 |
Maximum |
Power Handling |
150 W |
CW, reference |
Discharge Element |
90 V |
Gas discharge tube |
Surge Current |
10 kA (8/20 us) |
8/20 us waveform |
Grounding |
Ring terminal |
M4 lug, ground wire |
Body Material |
Machined brass |
Corrosion-resistant plating |
Weight |
119 g |
Approximate |
Typical Application |
5G base station, DAS, small cell, tower-top equipment |
Primary use case |
These values are reference data for this protection family and should be checked against the final production configuration.
Engineering Comparison
Applications
Installation and Grounding Notes
OEM and B2B Support
FAQ
Q: When should the gas discharge tube be replaced?
A: The 90 V tube is rated for 10 kA on an 8/20 us waveform. Following a major surge event, test the tube for leakage and hold-off performance. If it does not pass the relevant check, the tube can be replaced without changing the complete arrester.
Q: Will this N Male to N Female lightning arrester affect a DC - 6 GHz signal?
A: The reference insertion loss is 0.3 dB and the maximum VSWR is 1.35 across the passband. These values describe the expected RF impact for applicable antenna-line use and should be confirmed for the final configuration.
Q: Can this arrester be used indoors?
A: Yes. It can be fitted at an equipment-end cable run as well as at an entry point, creating an additional grounded protection stage for connected RF equipment.